{"id":18387,"feature_order":4,"feature_code":null,"name":"Reverberation Time","type":"O","intent":"Design spaces in accordance\r\nwith comfortable reverberation times that support speech intelligibility, vocal\r\neffort and are conducive to concentration.&nbsp;<br>","intervention":"This WELL feature requires\r\nthat steps be taken to address acoustical comfort, by controlling reverberation\r\ntime based on room functionality.","issue":"Reverberation time is the\r\nlength of time taken for a sound to decay by 60 dB from an initial impulse\r\nlevel. The length of reverberation time is a function of room size, surface\r\narea and sound absorbing properties of surface finishes. Spaces with longer\r\nreverberation times may be larger in volume with hard surfaces that reflect\r\nsound. Spaces with shorter reverberation may be smaller with softer surfaces\r\nthat absorb sound. Spaces with high reverberation may have increased ambient\r\nnoise levels and reduce speech intelligibility (e.g., public address, speech\r\nreinforcement and unamplified speech). Studies have shown that high\r\nreverberation times in classrooms increase auditory workload in students and\r\nreduce cognition, memory retention and concentration.<sup>1\u20134<\/sup> Similarly, studies have shown that high\r\nreverberation reduces speech intelligibility among hard of hearing and\r\nnon-native speaking populations.<sup>5\u20138<\/sup><br>","evidence":"Reverberation time can be\r\ncontrolled by adding absorptive surface finishes at ceilings, walls and\r\nfurniture.<sup>9\u201311<\/sup> Projects that can alter room geometry can\r\nchange layouts and room dimensions to support optimal reverberation times, as\r\nneeded. Reducing reflective surfaces, such as glass, drywall, stone or similar,\r\nwill also reduce reflected sound energy, which increases reverberation time.\r\nReducing reverberation time also allows audio equipment for\r\ntelecommunication\/AV, speech reinforcement or public address to operate with\r\nhigher speech intelligibility performance.<sup>5,12\u201314<\/sup><br>","implementation":"","impact":"","max_points":2,"concept_id":1739,"slug":"reverberation-time","gbd_exists":null,"review_summary":null,"citations":"<ol><li>Klatte M, Bergstr\u00f6m K, Lachmann T. Does noise affect learning? A short review on noise effects on cognitive performance in children. Front Psychol. 2013;4(August):1-6. doi:10.3389\/fpsyg.2013.00578<\/li><li>Klatte M, Hellbr\u00fcck J, Seidel J, Leistner P. Effects of Classroom Acoustics on Performance and Well-Being in Elementary School Children: A Field Study. Environ Behav. 2010;42(5):659-692. doi:10.1177\/0013916509336813<\/li><li>Venetjoki N, Kaarlela-Tuomaala A, Keskinen E, Hongisto V. The effect of speech and speech intelligibility on task performance. Ergonomics. 2006;49(11):1068-1091. doi:10.1080\/00140130600679142<\/li><li>Belojevi\u0107 G, \u00d6hrstr\u00f6m E, Rylander R. Effects of noise on mental performance with regard to subjective noise sensitivity. Int Arch Occup Environ Health. 1992;64(4):293-301. doi:10.1007\/BF00378288<\/li><li>Ihrig W, The National Academies of Sciences Engineering Medicine, Transportation Research Board. Improving Intelligibility of Airport Terminal Public Address Systems. 2017. doi:10.17226\/24839<\/li><li>Heylighen A, Rychtarikova M, Vermeir G. Designing Spaces for Every Listener. Univers Access Inf Soc. 2010;9(3):283-292.<\/li><li>The National Disability Authority\u2019s Centre for Excellence in Universal Design. Building for Everyone: A universal design approach. 2012:4-106.<\/li><li>Centre for Excellence in Universal Design. Internal environment and services. In: Building for Everyone: A Universal Design Approach. Centre for Excellence in Universal Design. http:\/\/universaldesign.ie\/Built-Environment\/Building-for-Everyone\/.<\/li><li>Architectural Joint Technical Committee AV-004 Acoustical. AS\/NZS 2107:2016. 2016:24.<\/li><li>General Services Administration. Sound Matters: How to Achieve Acoustic Comfort in the Contemporary Office. 2011. https:\/\/www.wbdg.org\/FFC\/GSA\/gsa_soundmatters.pdf.<\/li><li>General Services Administration, Service PB. PBS-P100 Facilities Standards for the Public Buildings Service. 2016;(March):333. doi:10.1017\/CBO9781107415324.004<\/li><li>ANSI\/INFOCOMM. ANSI\/INFOCOMM 10:2013 Audiovisual Systems Performance Verification. 2013.<\/li><li>InfoComm International. AV \/ IT Infrastructure Guidelines for Higher Education.<\/li><li>Publication BSIS. BSI Standards Publication - Sound system equipment - Part 4. 2011.<\/li><\/ol>","deleted_at":null,"equivalency_count":14,"faq_count":1,"resource_count":0,"feature_full_name":"S04 Reverberation Time","feature_faq_name":"S04 Reverberation Time-v2","max_core_points":1,"parts":[{"id":30755,"name":"Achieve Reverberation Time Thresholds","part_number":1,"points":2,"possible_points":null,"core_points":1,"possible_core_points":null,"min_points":0,"rer_points":0,"wor_points":0,"parent_part_id":null,"feature_id":18387,"note":"","slug":"1-achieve-reverberation-time-thresholds-15","note_position_override":"top","new_core_shell":null,"existing_core_shell":null,"new_occupied":null,"existing_occupied":null,"education":null,"retail":null,"mfr":null,"others":null,"photographic_verification":null,"gbd_exists":null,"hospitality":null,"assisted_living":null,"cultural_institutions":null,"public_assembly":null,"deleted_at":null,"na_alternative":0,"na_alternative_text":null,"leed_well":0,"part_prefix":"S04.1","feature_name":"Reverberation Time","parent":null,"sub_parts":[{"id":33063,"condition":"OR","part_id":30755,"deleted_at":null,"space_types_included":[{"id":1,"name":"All Spaces","name_plural":"all"}],"space_types_excluded":[{"id":3,"name":"Dwelling Units","name_plural":"dwelling units"},{"id":42,"name":"Guest Rooms","name_plural":"guest rooms"}],"options":[{"id":41991,"option_order":1,"name":"Reverberation time, design","description":"<!--[if !supportAnnotations]--><!--[endif]-->\r\n<p>For projects in which the room types listed in the table cumulatively make up at least 10% of occupiable project area, the following requirements are met:<\/p>\r\n\r\n<p><!--[if !supportAnnotations]--><\/p>\r\n<!--[endif]-->","description_alt":null,"space_property":null,"certification":null,"note":"<p>Where room types include multiple use types (e.g., learning and fitness) use the limits that include the lower reverberation time or range.<\/p>","sub_part_id":33063,"deleted_at":null,"note_position_override":"bottom","verification_note":"<p>Modeling Report<\/p>","verification_condition":"AND","requirements":[{"id":120640,"option_id":41991,"requirement_order":1,"description":"<p>Reverberation time is within the ranges shown in the following table:<\/p>\r\n\r\n<table border=\"1\" style=\"text-align:center\">\r\n\t<tbody>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p style=\"text-align:left\">Room Type<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>Room Volume, v (cubic {{well-unit}}feet|meters{{\/well-unit}})<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>Reverberation Time, t (seconds)<sup>5,9,10<\/sup><\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td rowspan=\"3\">\r\n\t\t\t<p style=\"text-align:left\">Areas for learning<\/p>\r\n\r\n\t\t\t<p style=\"text-align:left\">Areas for lectures<\/p>\r\n\r\n\t\t\t<p style=\"text-align:left\">Areas for conferencing<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>v &lt; {{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 0.6<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>{{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&le; v &le; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\r\n\t\t\t<p>&nbsp;<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 0.8<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>v &gt; {{well-unit}}20,000 ft<sup>3<\/sup>|570&nbsp;<span style=\"font-size:15px\">m<sup>3<\/sup><\/span><span style=\"font-size:15px\">{{\/well-unit}}<\/span><\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.0<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p style=\"text-align:left\">Areas with regularly used PA systems<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>N\/A<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.5<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p style=\"text-align:left\">Areas for dining<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>N\/A<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.0<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td rowspan=\"3\">\r\n\t\t\t<p style=\"text-align:left\">Areas for fitness<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>v &lt; {{well-unit}}10,000 ft<sup>3<\/sup>|280m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 0.8<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>{{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&le; v &le; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&nbsp;<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.1<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>v &gt; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.8<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td rowspan=\"2\">\r\n\t\t\t<p style=\"text-align:left\">Areas for music rehearsal<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>v &lt; {{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.1<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>{{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&le; v &le; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&nbsp;<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.4<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t<\/tbody>\r\n<\/table>","description_alt":null,"deleted_at":null,"photographic_verification":0}],"verifications":[{"id":3,"name":"Technical Document (Audited)","chinese_name":"\u6280\u672f\u6587\u6863\uff08\u5ba1\u8ba1\uff09","is_auditable":1,"scale_type":"Audited","note":null}],"pvgbs":[]},{"id":41992,"option_order":2,"name":"Reverberation time, performance","description":"<!--[if !supportAnnotations]--><!--[endif]-->\r\n<p>For projects in which the room types listed in the table cumulatively make up at least 10% of occupiable project area, the following requirements are met:<\/p>\r\n\r\n<p><!--[if !supportAnnotations]--><\/p>\r\n<!--[endif]-->","description_alt":null,"space_property":null,"certification":null,"note":"<p>Where room types include multiple use types (e.g., learning and fitness) use the limits that include the lower reverberation time or range.<\/p>\r\n\r\n<p>Refer to the Performance Verification Guidebook for information on sensor\/testing requirements, required testing duration and compliance calculations.<\/p>","sub_part_id":33063,"deleted_at":null,"note_position_override":"bottom","verification_note":"<p>Technical Document: A list of room volumes for all applicable spaces.<\/p>","verification_condition":"AND","requirements":[{"id":120641,"option_id":41992,"requirement_order":1,"description":"<p>Reverberation time is within the ranges shown in the following table:<\/p>\r\n\r\n<table border=\"1\" style=\"text-align:center\">\r\n\t<tbody>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p style=\"text-align:left\">Room Type<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>Room Volume, v (cubic {{well-unit}}feet|meters{{\/well-unit}})<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>Reverberation Time, t (seconds)<sup>5,9,10<\/sup><\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td rowspan=\"3\">\r\n\t\t\t<p style=\"text-align:left\">Areas for learning<\/p>\r\n\r\n\t\t\t<p style=\"text-align:left\">Areas for lectures<\/p>\r\n\r\n\t\t\t<p style=\"text-align:left\">Areas for conferencing<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>v &lt; {{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 0.6<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>{{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&le; v &le; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&nbsp;<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 0.8<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>v &gt; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.0<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p style=\"text-align:left\">Areas with regularly used PA systems<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>N\/A<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.5<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p style=\"text-align:left\">Areas for dining<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>N\/A<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.0<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td rowspan=\"3\">\r\n\t\t\t<p style=\"text-align:left\">Areas for fitness<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>v &lt; {{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 0.8<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>{{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&le; v &le; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&nbsp;<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.1<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>v &gt; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.8<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td rowspan=\"2\">\r\n\t\t\t<p style=\"text-align:left\">Areas for music rehearsal<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>v &lt; {{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.1<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t\t<tr>\r\n\t\t\t<td>\r\n\t\t\t<p>{{well-unit}}10,000 ft<sup>3<\/sup>|280 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&le; v &le; {{well-unit}}20,000 ft<sup>3<\/sup>|570 m<sup>3<\/sup>{{\/well-unit}}&nbsp;&nbsp;<\/p>\r\n\t\t\t<\/td>\r\n\t\t\t<td>\r\n\t\t\t<p>t &le; 1.4<\/p>\r\n\t\t\t<\/td>\r\n\t\t<\/tr>\r\n\t<\/tbody>\r\n<\/table>","description_alt":null,"deleted_at":null,"photographic_verification":0}],"verifications":[{"id":15,"name":"Performance Test","chinese_name":"\u6027\u80fd\u6d4b\u8bd5","is_auditable":0,"scale_type":"Individual","note":null},{"id":26,"name":"Technical Document (Individual)","chinese_name":"\u6280\u672f\u6587\u6863\uff08\u5355\u4f53\uff09","is_auditable":0,"scale_type":"Individual","note":null}],"pvgbs":[{"id":948,"option_id":41992,"name":"Reverberation Time","reporting_compliance":"<ul>\n\t<li>The average RT<sub>60<\/sub> value from 500 Hz - 1 kHz of the three measurements per measurement location is used to determine compliance with the WELL threshold.<\/li>\n<\/ul>","device_requirements":"<p>Balloon of minimum diameter 0.4 m [16 in]<\/p>\n\n<p><em>OR<\/em><\/p>\n\n<p>Loudspeaker:<\/p>\n\n<ul>\n\t<li>Minimum 0.25 m [10 in] diameter<\/li>\n\t<li>Minimum frequency response of at least 100 Hz &ndash; 4 kHz<\/li>\n\t<li>Maximum output of at least 100 dB<\/li>\n\t<li>Noise generator capable of producing pink noise signal of equal sound energy across all frequencies of interest<\/li>\n<\/ul>","alternative_requirements":null,"alternative_quantity":null,"quantity_override":null,"quantity_core_override":null,"recertification_override":null,"locations_override":null,"quantity_note":"<ul>\n\t<li>Three measurements of approximately 10 seconds (or however long is needed to capture impulse response across all frequencies) per measurement location.<\/li>\n\t<li>At least 10% of the total number of applicable spaces, with preference given to rooms that require higher degrees of speech intelligibility with the following order of descending priority: lecture rooms, classrooms and conference rooms.<\/li>\n<\/ul>","location_note":"<ul>\n\t<li>The HVAC system must be on during the measurement periods.<\/li>\n\t<li>Sound masking systems (if present) must be on during the measurements.<\/li>\n\t<li>The sampling points should be located at least 1 m [3.3 ft] from any sound-reflecting surfaces.<\/li>\n\t<li>The impulse sound source must be at least 1 m [3.3 ft] from both the sound measuring device and sound-reflecting surfaces.<\/li>\n<\/ul>","test_method_note":"<ul>\n\t<li>For the noise source impulse:\n\t<ul>\n\t\t<li>If generated via balloon burst, inflate balloon to 0.4 m [16 in] diameter. Then, arm or ready the sound level meter by measuring the baseline background noise level. Once the meter is armed for impulse, burst balloon using a pen or similar. Allow approximately 10 seconds for the meter to capture impulse response at all frequencies.<\/li>\n\t\t<li>If generated via loudspeaker, arm and ready the meter by measuring the baseline background noise level. Then, excite the room by turning the loudspeaker on to approximately 90 dBA using a white\/pink noise generator. Once the sound level meter is armed for impulse measurement, turn off the sound source and wait approximately 10 seconds for the sound level meter to capture the impulse response at all frequencies.<\/li>\n\t<\/ul>\n\t<\/li>\n<\/ul>","laboratory_requirement":null}]}]}],"on_sites":[],"annotated_documents":[],"letter_of_assurances":[],"part_guidances":[{"id":33168,"part_id":30755,"category":"WELL Core","sub_category":null,"rating_note":null,"alignment_note":null,"doc_guidance":"<p>Meet these requirements in non-leased spaces. To earn an additional point, also meet these requirements in leased spaces.<\/p><p><o:p><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;WELL Core projects where non-leased space represents 40% or more of total project area may pursue the additional point without achieving the feature requirements in tenant spaces. Projects utilizing this pathway should include a note on the documentation required by the feature.    &quot;}\" data-sheets-userformat=\"{&quot;2&quot;:33565633,&quot;3&quot;:{&quot;1&quot;:0},&quot;9&quot;:0,&quot;10&quot;:1,&quot;11&quot;:4,&quot;12&quot;:0,&quot;14&quot;:[null,2,0],&quot;16&quot;:12,&quot;28&quot;:1}\">WELL Core projects where non-leased space represents 40% or more of total project area may pursue the additional point without achieving the feature requirements in tenant spaces. Projects utilizing this pathway should include a note on the documentation required by the feature.&nbsp; &nbsp;&nbsp;<\/span><br><\/o:p><\/p>","points":"1"}],"methods":[]}],"ihmes":[],"sdgs":[{"id":11,"name":"11: Sustainable Cities and Communities","max_points":0}]}