{"id":18369,"feature_order":4,"feature_code":null,"name":"Electric Light Glare Control","type":"O","intent":"Minimize glare caused by electric light.","intervention":"This WELL feature requires projects to manage glare by using strategies, such as calculation of glare and choosing the appropriate light fixtures for the space.","issue":"<p>Glare is defined as excessive brightness of the light-source, excessive brightness-contrasts and excessive quantity of light<sup>1,2<\/sup>&nbsp;and is an integral part of lighting design. Reducing glare improves the visual experience of the occupants in the space. Glare has been associated with a host of health issues that range from visual discomfort and eye fatigue to headaches and migraines.<sup>1,3&nbsp;<\/sup>Studies have also shown that glare can lead to visual impairment and discomfort, which can cause accidents in the workplace. Individuals under the age of 50 are more sensitive to glare.<sup>4<\/sup>&nbsp;Since a substantial section of the workforce falls into this age group, it is important to address glare to avoid visual fatigue and glare-induced headaches.<o:p><\/o:p><\/p>","evidence":"Electric lighting, the light source, type of luminaires and lighting layout can help to reduce glare.&nbsp;","implementation":"","impact":"","max_points":2,"concept_id":1737,"slug":"electric-light-glare-control-1","gbd_exists":null,"review_summary":null,"citations":"<ol><li>Mainster MA, Turner PL. Glare\u2019s causes, consequences, and clinical challenges after a century of ophthalmic study. Am J Ophthalmol. 2012;153(4):587-593. doi:10.1016\/j.ajo.2012.01.008<\/li><li>Abrahamsson M, Sjostrand J. Impairment of contrast sensitivity function (CSF) as a measure of disability glare. Investig Ophthalmol Vis Sci. 1986;27(7):1131-1136.<\/li><li>Harle DE, Shepherd AJ, Evans BJW. Visual stimuli are common triggers of migraine and are associated with pattern glare. Headache. 2006;46(9):1431-1440. doi:10.1111\/j.1526-4610.2006.00585.x<\/li><li>Wolska A, Sawicki D. Evaluation of discomfort glare in the 50+ elderly: Experimental study. Int J Occup Med Environ Health. 2014;27(3):444-459. doi:10.2478\/s13382-014-0257-9<\/li><\/ol>","deleted_at":null,"equivalency_count":2,"faq_count":3,"resource_count":1,"feature_full_name":"L04 Electric Light Glare Control","feature_faq_name":"L04 Electric Light Glare Control-v2","max_core_points":1,"parts":[{"id":30729,"name":"Manage Glare from Electric Lighting","part_number":1,"points":2,"possible_points":null,"core_points":1,"possible_core_points":null,"min_points":0,"rer_points":0,"wor_points":0,"parent_part_id":null,"feature_id":18369,"note":"","slug":"1-manage-glare-from-electric-lighting-15","note_position_override":"top","new_core_shell":null,"existing_core_shell":null,"new_occupied":null,"existing_occupied":null,"education":null,"retail":null,"mfr":null,"others":null,"photographic_verification":null,"gbd_exists":null,"hospitality":null,"assisted_living":null,"cultural_institutions":null,"public_assembly":null,"deleted_at":null,"na_alternative":0,"na_alternative_text":null,"leed_well":0,"part_prefix":"L04.1","feature_name":"Electric Light Glare Control","parent":null,"sub_parts":[{"id":33031,"condition":"OR","part_id":30729,"deleted_at":null,"space_types_included":[{"id":1,"name":"All Spaces","name_plural":"all"}],"space_types_excluded":[{"id":20,"name":"Industrial","name_plural":"industrial"}],"options":[{"id":41947,"option_order":1,"name":"Luminaire considerations","description":"<p>All luminaires within regularly occupied spaces (excluding wall wash fixtures, concealed fixtures, emergency lighting and decorative fixtures installed as specified by the manufacturer) meet&nbsp;one of the following requirements when measured at light output representative of regular use conditions:<\/p>\r\n\r\n<p>&nbsp;<\/p>","description_alt":null,"space_property":null,"certification":null,"note":null,"sub_part_id":33031,"deleted_at":null,"note_position_override":"top","verification_note":"<p>Product specification sheets<\/p>","verification_condition":"AND","requirements":[{"id":120544,"option_id":41947,"requirement_order":1,"description":"<p>100% of light is emitted above the horizontal plane.<\/p>","description_alt":null,"deleted_at":null,"photographic_verification":0},{"id":120545,"option_id":41947,"requirement_order":2,"description":"<p>Classified with Unified Glare Rating (UGR) of 19&nbsp;or lower.<\/p>","description_alt":null,"deleted_at":null,"photographic_verification":0},{"id":120546,"option_id":41947,"requirement_order":3,"description":"<p>&nbsp;Luminance that does not exceed 6,000 cd\/m<sup>2<\/sup> at any angle between 45 and 90 degrees from nadir.<\/p>","description_alt":null,"deleted_at":null,"photographic_verification":0}],"verifications":[{"id":3,"name":"Technical Document (Audited)","chinese_name":"\u6280\u672f\u6587\u6863\uff08\u5ba1\u8ba1\uff09","is_auditable":1,"scale_type":"Audited","note":null}],"pvgbs":[]},{"id":41948,"option_order":2,"name":"Space considerations","description":"<p>All regularly occupied spaces meet the following requirement:<\/p>","description_alt":null,"space_property":null,"certification":null,"note":null,"sub_part_id":33031,"deleted_at":null,"note_position_override":"top","verification_note":"<p>Modeling report<\/p>","verification_condition":"AND","requirements":[{"id":120547,"option_id":41948,"requirement_order":1,"description":"<p>Classified with Unified Glare Rating (UGR) of 19&nbsp;or lower.<\/p>","description_alt":null,"deleted_at":null,"photographic_verification":0}],"verifications":[{"id":3,"name":"Technical Document (Audited)","chinese_name":"\u6280\u672f\u6587\u6863\uff08\u5ba1\u8ba1\uff09","is_auditable":1,"scale_type":"Audited","note":null}],"pvgbs":[]}]},{"id":33034,"condition":"OR","part_id":30729,"deleted_at":null,"space_types_included":[{"id":20,"name":"Industrial","name_plural":"industrial"}],"space_types_excluded":[],"options":[{"id":41951,"option_order":1,"name":"Luminaire considerations","description":"<p>All luminaires within regularly occupied spaces (excluding wall wash fixtures, concealed fixtures, emergency lighting and decorative fixtures installed as specified by the manufacturer) meet one of the following requirements when measured at light output representative of regular use conditions:&nbsp;<\/p>\r\n\r\n<p>&nbsp;<\/p>","description_alt":null,"space_property":null,"certification":null,"note":null,"sub_part_id":33034,"deleted_at":null,"note_position_override":"top","verification_note":"<p>Product specification sheets<\/p>","verification_condition":"AND","requirements":[{"id":120550,"option_id":41951,"requirement_order":1,"description":"<p>100% of light is emitted above the horizontal plane.<\/p>","description_alt":null,"deleted_at":null,"photographic_verification":0},{"id":120551,"option_id":41951,"requirement_order":2,"description":"<p>Classified with Unified Glare Rating (UGR) of 19 or lower.<\/p>","description_alt":null,"deleted_at":null,"photographic_verification":0},{"id":120552,"option_id":41951,"requirement_order":3,"description":"<p>Luminance that does not exceed 6,000 cd\/m<sup>2<\/sup> at any angle between 45 and 90 degrees from nadir.<\/p>","description_alt":null,"deleted_at":null,"photographic_verification":0}],"verifications":[{"id":3,"name":"Technical Document (Audited)","chinese_name":"\u6280\u672f\u6587\u6863\uff08\u5ba1\u8ba1\uff09","is_auditable":1,"scale_type":"Audited","note":null}],"pvgbs":[]},{"id":41952,"option_order":2,"name":"Space considerations","description":"<p>All regularly occupied spaces meet the following requirement:<\/p>","description_alt":null,"space_property":null,"certification":null,"note":null,"sub_part_id":33034,"deleted_at":null,"note_position_override":"top","verification_note":"<p>Modeling report<\/p>","verification_condition":"AND","requirements":[{"id":120553,"option_id":41952,"requirement_order":1,"description":"<p>Unified Glare Rating (UGR) of 19 or lower.<\/p>","description_alt":null,"deleted_at":null,"photographic_verification":0}],"verifications":[{"id":3,"name":"Technical Document (Audited)","chinese_name":"\u6280\u672f\u6587\u6863\uff08\u5ba1\u8ba1\uff09","is_auditable":1,"scale_type":"Audited","note":null}],"pvgbs":[]}]}],"on_sites":[],"annotated_documents":[],"letter_of_assurances":[],"part_guidances":[{"id":33143,"part_id":30729,"category":"WELL Core","sub_category":null,"rating_note":null,"alignment_note":null,"doc_guidance":"<p>Meet these requirements in non-leased spaces. To earn an additional point, also meet requirements in leased spaces.<\/p><p><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;WELL Core projects where non-leased space represents 40% or more of total project area may pursue the additional point without achieving the feature requirements in tenant spaces. Projects utilizing this pathway should include a note on the documentation required by the feature.    &quot;}\" data-sheets-userformat=\"{&quot;2&quot;:33565633,&quot;3&quot;:{&quot;1&quot;:0},&quot;9&quot;:0,&quot;10&quot;:1,&quot;11&quot;:4,&quot;12&quot;:0,&quot;14&quot;:[null,2,0],&quot;16&quot;:12,&quot;28&quot;:1}\">WELL Core projects where non-leased space represents 40% or more of total project area may pursue the additional point without achieving the feature requirements in tenant spaces. Projects utilizing this pathway should include a note on the documentation required by the feature.&nbsp; &nbsp;&nbsp;<\/span><br><\/p>","points":"1"}],"methods":[]}],"ihmes":[],"sdgs":[{"id":3,"name":"3: Good Health and Well-being","max_points":0}]}