{"id":14839,"feature_order":4,"feature_code":null,"name":"Sound Absorption","type":"O","intent":"Design\r\nspaces in accordance with comfortable reverberation times that support speech\r\nintelligibility and are conducive to focus.&nbsp; &nbsp;<br>","intervention":"<style> <\/style>\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n<p>This WELL feature requires steps be taken to address acoustical comfort by assigning requirements for surface finishes and reverberation time depending on the room functionality.<o:p><\/o:p><\/p>","issue":"In spaces that incorporate hard surface finish materials, reverberation time and reflected sound energy have the potential to build and create uncomfortable environments. For example, a space that is designed for learning, presenting, critical listening or a similar purpose will benefit from having a reverberation time that is conducive to high speech intelligibility and articulation class (i.e., the words or sounds that are intentionally introduced to that space are heard as needed by all occupants). In a classroom, for instance, this requires a reverberation time that is low enough to foster clear speech intelligibility but high enough to allow speech to project to all areas of the classroom.<sup>[CIT:69966,CIT:69998]<\/sup> From a universal design and accessibility standpoint, this focus on optimal acoustical design is crucial in designing spaces where all occupants can clearly understand information, sometimes critical information, that is being audibly presented.<sup>[CIT:69960,CIT:69984]<\/sup> Over-reverberance and reflected sound energy have the potential to interrupt audio-visual equipment in small spaces, in some instances even making phone calls unintelligible on the receiving and\/or source end.<sup>[CIT:69964]<\/sup> There may be instances where enhanced speech intelligibility is not ideal (e.g., office environments, restaurants) where focus or intimacy at a task plane is anticipated.<sup>[CIT:69999]<\/sup> Achieving optimal reverberation times in specific spaces is crucial for designing with acoustical comfort in mind.","evidence":"Controlling the effects of reverberant and reflected acoustical energy can be achieved via a number of combinations: by designing a space to meet specific reverberation times that are conducive to the intended programming therein, by providing absorptive finishes throughout an enclosure, or a combination of the two. Absorptive finishes can be classified by a number of metrics [e.g., Noise Reduction Coefficient (NRC, \u03b1<sub>w<\/sub> or equivalent), Articulation Class (AC)]. For best results, absorptive finishes are provided along surfaces that are located opposite harder surface finishes. If possible, absorption should exist at ceiling planes when floor finishes are programmed to be hard (i.e., wood, polished concrete or similar). Similarly, and where possible, absorptive wall finishes should complement opposite walls that are reflective (e.g., glass office fronts, fenestration).","implementation":"","impact":"<p>Designing a space\r\nwith reverberation time and reflected sound energy in mind can drastically\r\nimprove the comfort level of occupants in terms of critical listening, speech\r\nprojection, memory retention and speech privacy.<o:p><\/o:p><\/p>","max_points":3,"concept_id":1340,"slug":"sound-absorption","gbd_exists":null,"review_summary":null,"citations":null,"deleted_at":null,"equivalency_count":3,"faq_count":0,"resource_count":0,"feature_full_name":"S04 Sound Absorption","feature_faq_name":"S04 Sound Absorption-v2-pilot","max_core_points":3,"parts":[{"id":24506,"name":"Meet Thresholds for Reverberation Time","part_number":1,"points":1,"possible_points":null,"core_points":0,"possible_core_points":null,"min_points":0,"rer_points":0,"wor_points":0,"parent_part_id":null,"feature_id":14839,"note":"","slug":"","note_position_override":"bottom","new_core_shell":"1","existing_core_shell":"1","new_occupied":"1","existing_occupied":"1","education":"1","retail":"1","mfr":"0","others":"0","photographic_verification":null,"gbd_exists":null,"hospitality":"0","assisted_living":"0","cultural_institutions":"0","public_assembly":"0","deleted_at":null,"na_alternative":0,"na_alternative_text":null,"leed_well":0,"part_prefix":"S04.1","feature_name":"Sound Absorption","parent":null,"sub_parts":[{"id":26390,"condition":"OR","part_id":24506,"deleted_at":null,"space_types_included":[{"id":1,"name":"All Spaces","name_plural":"all"}],"space_types_excluded":[{"id":3,"name":"Dwelling Units","name_plural":"dwelling units"}],"options":[{"id":32978,"option_order":1,"name":null,"description":"<style> <\/style>\r\n\r\n\r\n\r\n\r\n\r\n\r\nThe following is achieved:","description_alt":null,"space_property":null,"certification":null,"note":null,"sub_part_id":26390,"deleted_at":null,"note_position_override":"bottom","verification_note":null,"verification_condition":"AND","requirements":[{"id":93479,"option_id":32978,"requirement_order":null,"description":"<p>\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n<\/p><p>Spaces meet the maximum RT<sub>(60)<\/sub>&nbsp;thresholds in the table below:&nbsp;<\/p><table border=\"1\"><tbody><tr><td><p><b>Room Type<\/b><\/p><\/td><td><p><b>Size<\/b><\/p><\/td><td><p><b>RT<sub>(60)&nbsp;<\/sub>(seconds)<\/b><\/p><\/td><\/tr><tr><td><p>Conference rooms<\/p><\/td><td><p>N\/A<\/p><\/td><td><p><span style=\"background-color: transparent;\">\u2264&nbsp;<\/span>0.6<\/p><\/td><\/tr><tr><td rowspan=\"3\"><p>Classrooms<\/p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/p><p>&nbsp;<\/p><\/td><td><p>&lt; 280 m\u00b3 [10,000 ft\u00b3]<\/p><\/td><td><p><span style=\"background-color: transparent;\">\u2264&nbsp;<\/span>0.6<\/p><\/td><\/tr><tr><td><p>Between 280 m\u00b3 [10,000 ft\u00b3] and 570m\u00b3 [20,000 ft\u00b3]<\/p><\/td><td><p>0.5 to 0.8<\/p><\/td><\/tr><tr><td><p>&gt; 570 m\u00b3 [20,000 ft\u00b3]<\/p><\/td><td><p>0.6 to 1.0<\/p><\/td><\/tr><tr><td rowspan=\"3\"><p>Lecture halls<\/p><\/td><td><p>&lt;&nbsp;280 m\u00b3 [10,000 ft\u00b3]<\/p><\/td><td><p><span style=\"background-color: transparent;\">\u2264&nbsp;<\/span>0.7<\/p><\/td><\/tr><tr><td><p>Between 280 m\u00b3 [10,000 ft\u00b3] and 570m\u00b3 [20,000 ft\u00b3]<\/p><\/td><td><p>0.6 to 0.9<\/p><\/td><\/tr><tr><td><p>&gt; 570 m\u00b3 [20,000 ft\u00b3]<\/p><\/td><td><p>0.7 to 1.3<\/p><\/td><\/tr><tr><td rowspan=\"2\"><p>Music rehearsal spaces<\/p><\/td><td><p>&lt;&nbsp;280 m\u00b3 [10,000 ft\u00b3]<\/p><\/td><td><p><span style=\"background-color: transparent;\">\u2264&nbsp;<\/span>1.1<\/p><\/td><\/tr><tr><td><p>Between 280 m\u00b3 [10,000 ft\u00b3] and 570m\u00b3 [20,000 ft\u00b3]<\/p><\/td><td><p>1.0 to 1.4<\/p><\/td><\/tr><tr><td rowspan=\"3\"><p>Fitness facilities<\/p><\/td><td><p>&lt; 280 m\u00b3 [10,000 ft\u00b3]<\/p><\/td><td><p>0.7 to 0.8<\/p><\/td><\/tr><tr><td><p>Between 280 m\u00b3 [10,000 ft\u00b3] and 570m\u00b3 [20,000 ft\u00b3]<\/p><\/td><td><p>0.8 to 1.1<\/p><\/td><\/tr><tr><td><p>&gt; 570 m\u00b3 [20,000 ft\u00b3]<\/p><\/td><td><p>1.0 to 1.8<\/p><\/td><\/tr><\/tbody><\/table><br>","description_alt":null,"deleted_at":null,"photographic_verification":null}],"verifications":[],"pvgbs":[]}]}],"on_sites":[{"id":3,"name":"Performance Test","intent_text":"Intent-phase documents can reflect a narrative of performance expectations.","implement_text":"Implementation-phase documents are not required, as performance tests are undertaken by a Performance Testing Agent.","is_auditable":0,"scale_type":"Individual","note":null}],"annotated_documents":[],"letter_of_assurances":[],"part_guidances":[{"id":28557,"part_id":24506,"category":"WELL Core","sub_category":"Option 3","rating_note":null,"alignment_note":null,"doc_guidance":"To earn\r\n  this optimization, the requirements should be met in the whole building.\r\n  Note: for WELL Core, achievement requires access to at least 10% of leased\r\n  space for testing.","points":null}],"methods":[{"id":2,"name":"Performance"}]},{"id":24511,"name":"Implement Sound Reducing Ceilings","part_number":2,"points":1,"possible_points":null,"core_points":0,"possible_core_points":null,"min_points":0,"rer_points":0,"wor_points":0,"parent_part_id":null,"feature_id":14839,"note":"","slug":"","note_position_override":"bottom","new_core_shell":"1","existing_core_shell":"1","new_occupied":"1","existing_occupied":"1","education":"1","retail":"1","mfr":"1","others":"0","photographic_verification":null,"gbd_exists":null,"hospitality":"0","assisted_living":"0","cultural_institutions":"0","public_assembly":"0","deleted_at":null,"na_alternative":0,"na_alternative_text":null,"leed_well":0,"part_prefix":"S04.2","feature_name":"Sound Absorption","parent":null,"sub_parts":[{"id":26396,"condition":"OR","part_id":24511,"deleted_at":null,"space_types_included":[{"id":1,"name":"All Spaces","name_plural":"all"}],"space_types_excluded":[{"id":3,"name":"Dwelling Units","name_plural":"dwelling units"}],"options":[{"id":32983,"option_order":1,"name":null,"description":"<p>Spaces have ceiling finishes that meet the following specifications:<sup>[CIT:70000]<\/sup><o:p><\/o:p><\/p>","description_alt":null,"space_property":null,"certification":null,"note":null,"sub_part_id":26396,"deleted_at":null,"note_position_override":"bottom","verification_note":null,"verification_condition":"AND","requirements":[{"id":93490,"option_id":32983,"requirement_order":null,"description":"<p>Ceiling treatment meets the minimum NRC\/ \u03b1<sub>w<\/sub>&nbsp;values described below:<\/p>\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n<table border=\"1\">\r\n <tbody><tr>\r\n  <td>\r\n  <p><b>Space Type<\/b><\/p><\/td><td><p><b>NRC\/ \u03b1<sub>w<\/sub><\/b><\/p>\r\n  <\/td>\r\n <\/tr>\r\n <tr>\r\n  <td>\r\n  <p>Open Workspaces<\/p>\r\n  <p>Enclosed Offices<\/p>\r\n  <p>Dining Spaces<\/p>\r\n  <\/td>\r\n  <td>\r\n  <p>0.7 for at least 75%\r\n  of available ceiling area<\/p>\r\n  <\/td>\r\n <\/tr>\r\n <tr>\r\n  <td>\r\n  <p>Conference Rooms<\/p>\r\n  <p>Classrooms<\/p>\r\n  <\/td>\r\n  <td>\r\n  <p>0.7 for at least 50%\r\n  of available ceiling area<\/p>\r\n  <\/td>\r\n <\/tr>\r\n<\/tbody><\/table>","description_alt":null,"deleted_at":null,"photographic_verification":null}],"verifications":[],"pvgbs":[]}]}],"on_sites":[],"annotated_documents":[{"id":21,"name":"Design Specifications","intent_text":"Intent-stage documents can reflect design specifications at any phase of design.","implement_text":"Implementation-stage documents must reflect as-built conditions, or 100% construction documents.","is_auditable":1,"scale_type":"Audited","note":null}],"letter_of_assurances":[],"part_guidances":[{"id":28564,"part_id":24511,"category":"WELL Core","sub_category":"Option 3","rating_note":null,"alignment_note":null,"doc_guidance":"To earn\r\n  this optimization, the requirements should be met in the whole building.&nbsp;","points":null}],"methods":[{"id":4,"name":"Design"}]},{"id":24514,"name":"Implement Sound Reducing Vertical Surfaces","part_number":3,"points":1,"possible_points":null,"core_points":0,"possible_core_points":null,"min_points":0,"rer_points":0,"wor_points":0,"parent_part_id":null,"feature_id":14839,"note":"","slug":"","note_position_override":"top","new_core_shell":"1","existing_core_shell":"1","new_occupied":"1","existing_occupied":"1","education":"1","retail":"1","mfr":"1","others":"0","photographic_verification":null,"gbd_exists":null,"hospitality":"0","assisted_living":"0","cultural_institutions":"0","public_assembly":"0","deleted_at":null,"na_alternative":0,"na_alternative_text":null,"leed_well":0,"part_prefix":"S04.3","feature_name":"Sound Absorption","parent":null,"sub_parts":[{"id":26399,"condition":"OR","part_id":24514,"deleted_at":null,"space_types_included":[{"id":1,"name":"All Spaces","name_plural":"all"}],"space_types_excluded":[{"id":3,"name":"Dwelling Units","name_plural":"dwelling units"}],"options":[{"id":32987,"option_order":1,"name":null,"description":"Spaces have wall finishes that meet following requirement:<sup>[CIT:70000]<\/sup>","description_alt":null,"space_property":null,"certification":null,"note":null,"sub_part_id":26399,"deleted_at":null,"note_position_override":"top","verification_note":null,"verification_condition":"AND","requirements":[{"id":93496,"option_id":32987,"requirement_order":null,"description":"<p>Wall treatments meet the minimum NRC\/\u03b1<sub>w<\/sub>&nbsp;values described below:<\/p>\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n<table border=\"1\">\r\n <tbody><tr>\r\n  <td>\r\n  <p><b>Space Type<\/b><\/p><\/td><td><p><b>NRC\/ \u03b1<sub>w<\/sub><\/b><\/p>\r\n  <\/td>\r\n <\/tr>\r\n <tr>\r\n  <td><p>Enclosed offices<\/p>\r\n  <p>Dining spaces<\/p>\r\n  <\/td>\r\n  <td>\r\n  <p>0.7 for at least 25%\r\n  of at least one wall<\/p>\r\n  <\/td>\r\n <\/tr>\r\n <tr>\r\n  <td>\r\n  <p>Conference rooms<\/p>\r\n  <p>Classrooms<\/p>\r\n  <\/td>\r\n  <td>\r\n  <p>0.7 for at least 25%\r\n  of at least two walls<\/p>\r\n  <\/td>\r\n <\/tr>\r\n<\/tbody><\/table>","description_alt":null,"deleted_at":null,"photographic_verification":null}],"verifications":[],"pvgbs":[]}]}],"on_sites":[],"annotated_documents":[{"id":21,"name":"Design Specifications","intent_text":"Intent-stage documents can reflect design specifications at any phase of design.","implement_text":"Implementation-stage documents must reflect as-built conditions, or 100% construction documents.","is_auditable":1,"scale_type":"Audited","note":null}],"letter_of_assurances":[],"part_guidances":[{"id":28568,"part_id":24514,"category":"WELL Core","sub_category":"Option 3","rating_note":null,"alignment_note":null,"doc_guidance":"To earn\r\n  this optimization, the requirements should be met in the whole building.&nbsp;","points":null}],"methods":[]}],"ihmes":[],"sdgs":[{"id":11,"name":"11: Sustainable Cities and Communities","max_points":0}]}